Accessibility Tools

Skip to main content

Follow Piva group
English
System CPT Fibra F.A. type 2
Insulating Panels

System CPT Fibra F.A. type 2



AVAILABLE THICKNESSES
From 40 to 120 mm. Other thicknesses available on request.
DIMENSIONS

Standard length: 1000 mm
Variable widths on request: from 550 to 1200 mm
Maximum length: 13000 mm

JOINT
Standard joint with the empty rib overlapping on the full rib.
TYPE OF INSULATION

Standard bulk density of the core: 90/100 kg/m3 ± 10%
(other densities available on request).

RIBS

The outer sheet has a profile with 5 ribs each 40 mm high, spaced at 250 mm centre-to-centre. The ribs are filled with mineral wood shaped measuring Blow=60 mm and Bupp=30 mm.

CERTIFICATIONS

Not envisaged in the UNI EN 14509:2013 standard for the CE marking as the internal support is perforated.

CERTIFICAZIONI ACUSTICHE

SYSTEM CPT FIBRA F.A. TYPE 2 panels have various acoustic certifications depending on their stratification and tested thickness. The certificates can be viewed in and downloaded from the reserved area on our website www.pivagroup.com.

SUPPORTS

Hot-dip galvanised steel (UNI EN 10346) pre-coated with coil coating cycles
Hot-dip galvanised steel (UNI EN 10346) pre-coated and embossed
Plastic-coated steel: (UNI EN 10147)
Natural aluminium, pre-coated and/or embossed: (UNI EN 9003/3 and UNI EN 10372)
AISI 304-316-340 stainless steel with 2B finish: (UNI EN 10088-1:2014)
Pre-coated stainless steel

THICKNESS OF SUPPORTS
From 0.5 mm to maximum 1.2 mm. Other thicknesses are available on request.
SHEET METAL PERFORATION

Inner and outer supports perforated through punching with Ø=4 mm holes, pitch 6 mm, over a length of 940 mm. Perforation percentage roughly 40%. Other types of perforations, pitches or perforation percentages are available on request depending on the necessary quantities.
Available thicknesses 0.5-0.6-0.8 mm.

Brochure PUR